Model No.:  YLD

Product Description



Model NO.: YLD


Application: Water Treatment


Disinfection Method: Ultraviolet


Bactericidal Efficienc: 98% Kill Total Coliforms


Power: 9600W


Lifespan of UV Lamp: 9000-12000 Hours


System Working Pressure Resistance: (0.6 MPa)6kg/Cm2


Brand of Ballast: Beasun


Specification: CE, SGS


HS Code: 842121999




Certification: BV, ISO9001, SGS, CE


Voltage: 220V


Item: Open Channel UV Water Treatment System


Material: Stainless Steel Ss304, Ss316


Lamps: 30PCS*320W


Power Supply: 110V~480V Can Be Changed


Raw Water: Watsewater, Municipal, Aquaculture Recirculating


Trademark: YLD


Origin: Jiangyin, Jiangsu


High Efficient Open Channel UV Lamps System For Waste Water Treatment



Open channel UV Water Sterilizer systems are mainly used at the municipal water/wastewater treatment plants for water recycling and effluent disinfection to ensure a better level of environmental protection.

UV disinfection is an effective and environmentally friendly alternative to the conventional chlorine effluent disinfection. Nowadays more than 15% of 2000 waste water treatment plants in North America have chosen the UV as the primary disinfection method. UV disinfection has proved its safety, reliability, efficiency, and economical characteristics over the years.

Open channel UV sterilziers GT series have been used for waste water, sewage water desinfection in order to achieve a lower envirionment pollution drainage.



Water quality factors that affect the disinfection efficiency and performance of the sewer UV water sterilizer system

1. Industrial waste water components of the incoming wale

2. The upstream treatment process and the chemical agents used

3. The UV light transmittance of the incoming flow

4. Content of the suspended matters

5. Particle size distribution



Disinfection system factors that affect the disinfection efficiency and performance of the sewer UV water sterilizer system



1. Hydrodynamic design of the sterilizer (Maximize the use of UV performance to increase the disinfector efficiency and reduce the water pressure loss

2. Lamp tube performance (including the system aging)

3. Arrangement of lamp tubes

4. Scale coefficient of lamp tubes

5. Performance of ballast



Design of the concise and lightweight bent frame

1. IP68 or equal grade of sealing protection. High-efficient secure multi-level sealing waterproof design.

2. The module adopts the push-in connectors with the less water resistance so as to guarantee the water incoming before disinfection and water discharge after disinfection.

3. There is little change in water level as to guarantee a stable sterilization effect.

4. It does not need any special tools to disassemble and assemble the disinfection module.



To customers details

Deatils:

01. What is the source of raw water to be treated?

--is it underground water or well water?or river water ,other source?

02. What is the capacity(m3/hour) you required for this sterilizer?

--most IMPORTANT requirement.

03. What will the treated water be used for?

--for human drinking or industry purpose?

04. What is the power supply in your country?





Typical Applications Wide range of clean / waste water treatment
Lamp Type Low-pressure, high-efficiency amalgam (monochromatic)
Ballast Type Electronic, high-efficiency, variable output (60~100% power)
Input Power Per Lamp 320, 550 Watts/pc
Lamp Configuration Horizontal, parallel to flow; Vertical to flow; 65°with the folow
Lamp Brand & Origin Lightsource/Philip/Heraeus/Domestic brand
Module Configuration 8, 10 or 12 lamps per module
Level Control Device Options Automatic Level Controller, Fixed weir or motorized weir gate
Water Level Sensor 1 electrode low water level sensor per channel
UV Intensity Sensor 1 UV detector for one sterilizer module
Working Temperature 4~60ºC/39.2~140ºF
Working Pressure 6 bar / 100psi
Enclosure Ratings
Module Frame/Ballast Enclosure TYPE 6P (IP68) / TYPE 6P (IP67)
All Other Enclosures TYPE 4X (IP56)
Ballast Cooling Method Convection / Air conditioning / Forced air required
Installation Location Indoor or outdoor
Module Frame/Chamber SS304/SS316, Internal finish - Ra(max)0.8um
Sleeve Cleaning System
Auto-Cleaning System Automatic Chemical/Mechanical (optional)
Auto-Cleaning WW Gel Non-corrosive, operator-friendly, food-grade
Sleeve Spec Quartz sleeves, UV transmittance >92%
Controller PLC-based (Siemens/ Schneider PLC Standard Platform)
Electrical Requirements
Power Supply 220V, 50Hz (can be customized )
Electrical Cabinet Working temperature 4~50ºC/39.2~122ºF, with power cord(2.5M)

Contact us if you need more details on Water Treatment. We are ready to answer your questions on packaging, logistics, certification or any other aspects about RO SystemUV Sterilizer. If these products fail to match your need, please contact us and we would like to provide relevant information.