Find Sand Filter, Sand Filter Tank, Automatic Sand Filter on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Sand Filter > Swimming Pool Sand Filter > Swimming Pool Water Filtration Sand Filters

Swimming Pool Water Filtration Sand Filters

Basic Info

Model No.:  YLD-SF-1000

Product Description



Model NO.: YLD-SF-1000


Usage: Environmental Protection, Chemical Industry


Style: Vertical


Certification: CE


CE Authentication: CE


Power Supply: AC380V 35A 50Hz


Specification: CE, ISO


HS Code: 8421219990




Type: Water Filter


Motive Force: Pressure


Performance: Sophisticated Filters


Quality Authentication: ISO9001:2008


Material for Filtration Tank: Stainless Steel/ Carbon Steel


Trademark: YLD


Origin: Jiangyin, Jiangsu, China




Swimming pool water filtration sand filters



Product Introduction

By-pass filter for chilled water as a by-pass filtering equipment of closed industrial circulating water is used to filter the circulating chilled water and its control modes consist of manual backwash and automatic backwash. The system is generally backwashed once every three to seven days in the circulating process, effectively improving the quality of chilled water and ensuring excellent and stable water quality after intervention to long-term running. The device has small water consumption and is widely used in the cleaning of all types of industrial and commercial chilled water circulation system as well as refrigerant water and heat medium water systems of central air conditioning, improving the stability of equipment operation. Users may weld and conned in parallel the by-pass filters in main return pipes depending on the conditions of circulation system and the pipe diameter should be determined based on the retaining water yield of parallel circulating water. The sewage water is then discharged into the sewerage network.















Working principle For the by-pass filtration, the filter is installed in the main circulating pipeline to filter all the circulating water, but a part of the circulating water led from the main circulating pipeline is filtered, which is a repeated circulating interception step by step to filter the impurities within the system and finally remove the impurities by the necessary backwash out of the system. Installing a by-pass filter in the circulating water system can prevent the terminal pipe of device from sludge blocking and remove the impurities in the system with chemical dosing. By-pass filtration is used to reduce the turbidity of the water circulation system, exactly, to reduce slime and prevent its deposition in the heat exchanger, so that the effect of agent will be better.









Generally speaking, if your filter is a quartz Sand Filter, it usually has two main functions:

1. To reduce suspended solids (turbidity). Otherwise, as the system is running, suspended solids increases, which will exacerbate the deposition and other problems.

2. Degreasing. Especially the oily turbid circulation, such as steel rolling and continuous casting, has high oil content and is easy for breeding microorganism and blocking the nozzles.



Technical description of by-pass filter for the industrial circulating water

Flow filter flow is designed according to 5% to 10% of the total circulation volume (the by-pass filter flow of the cooling water is designed by 10 % of the circulation volume and the by-pass filter flow of chilled water is designed by 5% of the circulation volume) and the filtration rate is designed by 20 - 3Smih according to water quality of the system. Specific to corrosive suspended solids of the circulating water system as well as the control, our technical support team has designed a variety of manual/automatic by-pass filtrating equipment in line with customer demand.



The characteristics of the filtration system

1. Manual or automatic control is available;

2. Water distributor is simple, uniform and reliable;

3. Finished water collector has high strength and long service life;

4. Easy to install. Only connect the inlet and outlet to the waste pipe when installing;

5. Less water consumption in backwash: a homogeneous filter is used, so that backwash cycle is extended and the total backwash water volume is greatly reduced;

6. High backwash efficiency: an advanced water collector is used, ensuring efficient backwash effect.









Technical Parameters:



Equipment parameter


Model

Flow Rate
(m3/H)

Inlet and outlet
(mm)

Filter area
(m2)

Diameter
(mm)

Height
(mm)

YLD-SF-800

15-25

50

0.5

800

960

YLD-SF-1000

23-39

50

0.79

1000

1200

YLD-SF-1200

33-55

80

1.13

1200

1400

YLD-SF-1400

45-75

100

1.54

1400

1600

YLD-SF-1600

60-100

100

2.01

1600

1800

YLD-SF-1800

75-125

150

2.54

1800

1950

YLD-SF-2000

95-155

150

3.14

2000

2150

YLD-SF-2200

115-190

150

3.80

2200

2250

YLD-SF-2400

130-210

150

4.52

2400

2300

YLD-SF-2600

145-225

150

5.3

2600

2400

YLD-SF-2800

155-240

200

6.15

2800

2500

YLD-SF-3000

170-255

200

7.00

3000

2600





Contact us if you need more details on Sand Filter. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Swimming Pool Filter、Water Filter. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Sand Filter > Swimming Pool Sand Filter