Find UV Sterilizer, UV Sterilizer System, UV Water Sterilizer on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Ultraviolet Sterilizer > UV Water Sterilizer > 254nm UV Lamp Sterilizer for Drinking Water Disinfection Treatment

254nm UV Lamp Sterilizer for Drinking Water Disinfection Treatment

Basic Info

Model No.:  YLC-360

Product Description

Model NO.: YLC-360 Material: Stainless Steel Ss304, Ss316 Interface Type: Flange or Thread System Working Pressure Resistance: <(0.6 MPa)6kg/Cm2 Working Temperature: 1-60 Centigrades Trademark: YLD Origin: Jiangyin, China Bactericidal Efficienc: 98% Kill Total Coliforms Lifespan of UV Lamp: > Continuous 9000 Hours Flow Rate: 0.3--1000 Ton/Hour Raw Water Supplying: Running Water,Pond Water,Swimming Pool Water,etc. Single UV Lamp Power: 25/40/80/105/120/150/320W Specification: CE, SGS, ISO, BV HS Code: 8421219990 Product description Ultraviolet light treatment is a widely recognized and proven method of disinfection of water and has several advantage over other disinfection methods such as chlorination, ozonation, etc….UV light does not add anything to the water ,such as ,undesirable color ,odor , taste , or flavor ,nor does it generate harmful byproducts. It adds only energy in the UV radiation. Also, UV disinfection requires only a fraction of the contact times required by other disinfection methods. It is fast, efficient, effective, economical and environmentally-friendly.   Working Principle UV water disinfection system design has been carefully conceived to provide adequate germicidal dosage throughout the disinfection chamber. The dosage, as it applies to UV disinfection, is a function of time and the intensity of UV radiation to which the water is exposed. Exposure time is related to the flow rate, the higher the flow rate, the lower the exposure time or the lower the flow rate, the higher the exposure time. The UV intensity is the amount of energy, per unit time, emitted by germicidal lamp. The Dosage is the product of UV intensity and the exposure time.
  254nm UV Lamp Sterilizer for Drinking Water Disinfection Treatment Limitation of Use The UV water disinfection system NOT intended for the treatment of water that has an obvious contamination or intentional source, such as raw sewage, nor is the unit intended to convert wastewater to microbiologically safe drinking water.     254nm UV Lamp Sterilizer for Drinking Water Disinfection Treatment                                Water Quality (Feed in)   Water quality plays a major role in the transmission of germicidal UV rays. It is recommended that the water does not exceed following maximum concentration levels    Maximum Concentration Levels (Very Important)  

Iron

≤0.3ppm(0.3mg/L)

Hardness

≤7gpg(120mg/L)

Turbidity

≤1NTU

Manganese

≤0.05ppm(0.05mg/L)

Tannins

≤0.1ppm(0.3mg/L)

UV Transmittance

≥750‰

   Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures to improve water quality to treatable levels. If, for any reason, it is believed the UV transmission is not satisfactory, contact the factory. 254nm UV Lamp Sterilizer for Drinking Water Disinfection Treatment

UV wavelength (nm)
Bacterial cells will die in the UVC(200-280mm) irradiation. 253.7nm spectral line of low pressure mercury lamp has high bactericidal effect and concentrates more than 900‰ output energy of low-pressure mercury UV  lamp.
  UV dose
The units generate a UV dosage of at least 30,000microwatt-seconds per square centimeter (μW-s/cm2), even at the end-of lamp life(EOL), which is more than sufficient to destroy most waterborne microorganisms, such as bacteria, yeasts, algae etc.
254nm UV Lamp Sterilizer for Drinking Water Disinfection Treatment

                 DOSAGE is the product of intensity & time

dosage=intensity*time=micro watt/cm2*time=microwatt-seconds per square centimeter

                              (μW-s/cm2)

               Note:1000μW-s/cm2=1mj/cm2(milli-joule/cm2)

As a general guideline, the following are some typical UV transmission rates (UVT)

City water supplies

850-980‰

De-ionized or Reverse Osmosis water

950-980‰

Surface waters(lakes, rivers, etc)

700-900‰

Ground water(wells)

900-950‰

Other liquids

10-990‰

  Advantages Effective: Virtually all microorganisms are susceptible to UV disinfection Automatic: Continuous or intermittent disinfection without special attention Fast: Water is ready for consumption as soon as it leaves the cell Easy: Simple installation and maintenance. Minimum space requirements Safe: No danger or way of overdosing, no addition of hazardous chemicals Economical: Hundreds of gallons of water can be purified for a few cents per day No Chemicals: No chlorine taste or corrosion problems   Technical Parameter
 
Model
Water Flow Power Inlet/Outlet
Diameter
Reactor
Diameter(L*W*H)
Control
Cabinet(L*W*H)
(m3/h) W mm in mm mm
YLCn-005 0.3 16 20 1/2" 350*63*110 N/A
YLCn-008 1 25 20 1/2" 470*63*110 N/A
YLCn-050 2 40 25 1" 930*76*130 N/A
YLCn-150 6 80 32 1+1/4" 930*108*240 250*140*300
YLCn-200 8 120 40 1+1/2" 930*133*270 250*140*300
YLCn-300 12 160 50 2" 930*159*290 300*150*400
YLC-360 15 200 65 2+1/2" 930*159*370 300*150*400
YLC-500 20 240 65 2+1/2" 930*159*370 300*150*400
YLC-600 25 280 80 3" 930*159*370 300*150*400
YLC-700 30 320 100 4" 930*159*370 300*150*400
YLC-1000 40 360 100 4" 930*159*370 350*200*450
YLC-1200 50 400 125 5" 930*219*450 350*200*450
YLC-1500 60 420 150 6" 1630*219*450 400*200*500
YLC-2000 80 560 150 6" 1630*219*450 400*200*500
YLC-2500 100 700 150 6" 1630*219*450 400*200*500
YLC-3000 125 840 150 6" 1630*219*450 500*200*600
YLC-4000 150 1120 200 8" 1630*273*530 500*200*600
YLC-5000 200 1400 200 8" 1630*273*530 500*200*600
YLC-7000 300 2100 250 10" 1630*325*580 500*350*1000
YLC-10K 400 2520 250 10" 1630*325*580 500*350*1000
YLC-15K 600 3080 300 12" 1630*377*640 600*350*1200
   Application   254nm UV Lamp Sterilizer for Drinking Water Disinfection Treatment
1.Food processing industry, including juices, milk, drinks, beer, practical oil  and canned food.
2.Electronic industry. 
3.Hospitals, various laboratory and high levels of pathogenic body water disinfection.
4.Households building, residential, office buildings, hotels, restaurants, water factories.
5.Purification and disinfection of shellfish, fish cleaning and disinfection process
6.Military camp, field water supply system
7.Urban wastewater disinfection. 
8.Swimming pool, other recreational water disinfection  
9.Thermal power, nuclear power plant  industrial, central air conditioning system cooling water. 
10.Biological, chemical and pharmaceutical, cosmetics for the production of cooling water. 
11.Sea water, fresh water breeding, aquaculture  water

To Customers 1.What is the water flow of your water system? 2.What is your raw water to be disinfected? 3.Do you need the Accessories like flow switch,UV intensity detector,timer,etc? 4.Do you also require other kinds of filters for prefiltration used in your water system?
 

Contact us if you need more details on UV Sterilizer. We are ready to answer your questions on packaging, logistics, certification or any other aspects about UV Lamp Sterilizer、UV Light Sterilizer. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Ultraviolet Sterilizer > UV Water Sterilizer