Basic Info

Model No.:  YLC-700

Product Description

Model NO.: YLC-700 Application: Industry Disinfection Method: Ultraviolet Material: Stainless Steel Ss304, Ss316 Interface Type: Flange Alert System for Lamp: One Set Raw Water Supplying: Running Water Lamp Brand: Light Source/Philips Specification: CE, SGS, ISO HS Code: 8421219990 Certification: BV, ISO9001, SGS, CE Voltage: 110V/220V/380V Bactericidal Efficienc: 98% Kill Total Coliforms Lifespan of UV Lamp: 9000-12000 Hours Flow Rate: 30 Ton/Hour System Working Pressure Resistance: (0.6 MPa)6kg/Cm2 Brand of Ballast: Beasun Trademark: YLD Origin: Jiangyin, Jiangsu Automatic Self Cleaning UV Water Sterilizer


The need for disinfection
Cooling towers are used to dissipate heat produced by industrial processes such as power generation, oil refining and chemical processing. They generally work in two ways, either through the evaporation of water to remove heat and cool the process fluid, or relying solely on air to cool the fluid. Towers utilizing water evaporation are an ideal breeding ground for microorganisms - many of them pathogenic - which thrive in the warm, wet conditions, forming 'biofilms'. Various species of Legionella bacteria, the cause of Legionnaires' disease in humans, are commonly associated with cooling towers and must be controlled by law. In addition to the health risks for surrounding populations, biofilms also cause many mechanical problems with the cooling process, such as a reduction in heat transfer, microbial corrosion, interference with the effectiveness of corrosion inhibitors, and disruption of water flow.
There are several ways of controlling microbial infection, including biocides such as chlorine, chlorine dioxide, hypobromite and ozone. In addition, a non-chemical method that is gaining increasing acceptance is ultraviolet (UV) disinfection.
Whatever treatment method is used faces many demands and needs to meet the following criteria:
 it should be effective against all microorganisms
 it should work fast
 it should have a residual effect
 it should be cost effective
 it should be easy to use
 it should have minimal environmental impact
It is often recommended that two treatment methods are used simultaneously to control biofilms and Legionella. UV, in combination with another biocide, meets all of the above criteria, with much reduced reliance on the secondary biocide.



model
Processing capacity (Ton/Hour) power (W)  inlet and outlet
(inch)
working pressure (Kg/cm 2 ) malfunction alert for UV lamp reactor dimension (cm) L×W×H dimension of panel(cm) anchor bolt  (cm) overall weight (Kg)
YLCn-005 0.3 16 1/2" 6 matched 30×6×11     5
YLCn-008 1 25 1/2" 6 matched 47×6.3×11     10
YLCn-050 2 40 1" 6 matched 100×9×20 Φ8.9×25
(diameter×length)
69×4×Φ1 25
YLCn-150 6 80 1+1/4" 6 matched 100×11×23 69×4×Φ1 30
YLCn-200 8 120 1+1/2" 6 matched 100×15.9×30 Φ8.9×45
(diameter×length)
69×7×Φ1 35
YLCn-300 12 160 2" 6 matched 100×15.9×32 69×7×Φ1 40
YLC-050 2 40 DN25/1" 6 matched 100×8.9×30 25×30×12
(L×H×w)
60×4×Φ1 45
YLC-150 6 80 DN32/1 1/4 " 6 matched 100×10.8×30 60×4×Φ1 50
YLC-200 8 120 DN40/1 1/2 " 6 matched 100×15.9×40 60×7×Φ1 60
YLC-300 12 160 DN50/2" 6 matched 100×15.9×40 60×7×Φ1 70
YLC-360 15 200 DN65/2 1/2" 6 matched 100×15.9×40 50×78×25
(L×H×W)
60×7×Φ1 120
YLC-500 20 240 DN65/2 1/2" 6 matched 100×21.9×50 60×11×Φ1.2 130
YLC-600 25 280 DN80/3" 6 matched 100×21.9×50 60×11×Φ1.2 140
YLC-700 30 320 DN100/4" 6 matched 100×21.9×50 60×11×Φ1.2 150
YLC-1000 40 360 DN100/4" 6 matched 100×21.9×50 60×11×Φ1.2 160
YLC-1200 50 400 DN125/5" 6 matched 100×21.9×50 60×11×Φ1.2 180
YLC-1500 60 420 DN150/6" 6 matched 170×27.3×57 120×16×Φ1.4 210
YLC-2000 80 560 DN150/6" 6 matched 170×27.3×57 120×16×Φ1.4 220
YLC-2500 100 700 DN150/6" 6 matched 170×27.3×57 60×128×30
(W×H×T)
 
120×16×Φ1.4 275
YLC-3000 125 840 DN150/6" 6 matched 173×27.3×57 120×16×Φ1.4 300
YLC-4000 150 1120 DN200/8" 6 matched 173×32.5×65 120×20×Φ1.6 325
YLC-5000 200 1400 DN200/8" 6 matched 173×37.7×72 120×22×Φ1.6 350
YLC-7000 300 2100 DN250/10" 6 matched 175×42.6×80 120×24×Φ2.0 400
YLC-10K 400 2520 DN250/10" 6 matched 176×52.9×95 60×150×40
(W×H×T)
120×28×Φ2.2 475
YLC-15K 600 3080 DN300/12" 6 matched 176×78×110 120×32×Φ2.4 600
YLC-20K 800 3920 DN350/14" 6 matched confirmed  confirmed confirmed confirmed
YLC-25K 1000 4760 DN350/14" 6 matched confirmed confirmed confirmed

Contact us if you need more details on UV Sterilizer. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Ultraviolet LampUltraviolet Water Sterilizer. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Ultraviolet Sterilizer > UV Water Sterilizer