Automatic Self Cleaning UV Water Sterilizer
Basic Info
Model No.: YLC-700
Product Description
Model NO.: YLC-700 Application: Industry Disinfection Method: Ultraviolet Material: Stainless Steel Ss304, Ss316 Interface Type: Flange Alert System for Lamp: One Set Raw Water Supplying: Running Water Lamp Brand: Light Source/Philips Specification: CE, SGS, ISO HS Code: 8421219990 Certification: BV, ISO9001, SGS, CE Voltage: 110V/220V/380V Bactericidal Efficienc: 98% Kill Total Coliforms Lifespan of UV Lamp: 9000-12000 Hours Flow Rate: 30 Ton/Hour System Working Pressure Resistance: (0.6 MPa)6kg/Cm2 Brand of Ballast: Beasun Trademark: YLD Origin: Jiangyin, Jiangsu Automatic Self Cleaning UV Water Sterilizer
The need for disinfection
Cooling towers are used to dissipate heat produced by industrial processes such as power generation, oil refining and chemical processing. They generally work in two ways, either through the evaporation of water to remove heat and cool the process fluid, or relying solely on air to cool the fluid. Towers utilizing water evaporation are an ideal breeding ground for microorganisms - many of them pathogenic - which thrive in the warm, wet conditions, forming 'biofilms'. Various species of Legionella bacteria, the cause of Legionnaires' disease in humans, are commonly associated with cooling towers and must be controlled by law. In addition to the health risks for surrounding populations, biofilms also cause many mechanical problems with the cooling process, such as a reduction in heat transfer, microbial corrosion, interference with the effectiveness of corrosion inhibitors, and disruption of water flow.
There are several ways of controlling microbial infection, including biocides such as chlorine, chlorine dioxide, hypobromite and ozone. In addition, a non-chemical method that is gaining increasing acceptance is ultraviolet (UV) disinfection.
Whatever treatment method is used faces many demands and needs to meet the following criteria:
it should be effective against all microorganisms
it should work fast
it should have a residual effect
it should be cost effective
it should be easy to use
it should have minimal environmental impact
It is often recommended that two treatment methods are used simultaneously to control biofilms and Legionella. UV, in combination with another biocide, meets all of the above criteria, with much reduced reliance on the secondary biocide.
Contact us if you need more details on UV Sterilizer. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Ultraviolet Lamp、Ultraviolet Water Sterilizer. If these products fail to match your need, please contact us and we would like to provide relevant information.
The need for disinfection
Cooling towers are used to dissipate heat produced by industrial processes such as power generation, oil refining and chemical processing. They generally work in two ways, either through the evaporation of water to remove heat and cool the process fluid, or relying solely on air to cool the fluid. Towers utilizing water evaporation are an ideal breeding ground for microorganisms - many of them pathogenic - which thrive in the warm, wet conditions, forming 'biofilms'. Various species of Legionella bacteria, the cause of Legionnaires' disease in humans, are commonly associated with cooling towers and must be controlled by law. In addition to the health risks for surrounding populations, biofilms also cause many mechanical problems with the cooling process, such as a reduction in heat transfer, microbial corrosion, interference with the effectiveness of corrosion inhibitors, and disruption of water flow.
There are several ways of controlling microbial infection, including biocides such as chlorine, chlorine dioxide, hypobromite and ozone. In addition, a non-chemical method that is gaining increasing acceptance is ultraviolet (UV) disinfection.
Whatever treatment method is used faces many demands and needs to meet the following criteria:
it should be effective against all microorganisms
it should work fast
it should have a residual effect
it should be cost effective
it should be easy to use
it should have minimal environmental impact
It is often recommended that two treatment methods are used simultaneously to control biofilms and Legionella. UV, in combination with another biocide, meets all of the above criteria, with much reduced reliance on the secondary biocide.
model | Processing capacity (Ton/Hour) | power (W) | inlet and outlet (inch) | working pressure (Kg/cm 2 ) | malfunction alert for UV lamp | reactor dimension (cm) L×W×H | dimension of panel(cm) | anchor bolt (cm) | overall weight (Kg) |
YLCn-005 | 0.3 | 16 | 1/2" | 6 | matched | 30×6×11 | 5 | ||
YLCn-008 | 1 | 25 | 1/2" | 6 | matched | 47×6.3×11 | 10 | ||
YLCn-050 | 2 | 40 | 1" | 6 | matched | 100×9×20 | Φ8.9×25 (diameter×length) | 69×4×Φ1 | 25 |
YLCn-150 | 6 | 80 | 1+1/4" | 6 | matched | 100×11×23 | 69×4×Φ1 | 30 | |
YLCn-200 | 8 | 120 | 1+1/2" | 6 | matched | 100×15.9×30 | Φ8.9×45 (diameter×length) | 69×7×Φ1 | 35 |
YLCn-300 | 12 | 160 | 2" | 6 | matched | 100×15.9×32 | 69×7×Φ1 | 40 | |
YLC-050 | 2 | 40 | DN25/1" | 6 | matched | 100×8.9×30 | 25×30×12 (L×H×w) | 60×4×Φ1 | 45 |
YLC-150 | 6 | 80 | DN32/1 1/4 " | 6 | matched | 100×10.8×30 | 60×4×Φ1 | 50 | |
YLC-200 | 8 | 120 | DN40/1 1/2 " | 6 | matched | 100×15.9×40 | 60×7×Φ1 | 60 | |
YLC-300 | 12 | 160 | DN50/2" | 6 | matched | 100×15.9×40 | 60×7×Φ1 | 70 | |
YLC-360 | 15 | 200 | DN65/2 1/2" | 6 | matched | 100×15.9×40 | 50×78×25 (L×H×W) | 60×7×Φ1 | 120 |
YLC-500 | 20 | 240 | DN65/2 1/2" | 6 | matched | 100×21.9×50 | 60×11×Φ1.2 | 130 | |
YLC-600 | 25 | 280 | DN80/3" | 6 | matched | 100×21.9×50 | 60×11×Φ1.2 | 140 | |
YLC-700 | 30 | 320 | DN100/4" | 6 | matched | 100×21.9×50 | 60×11×Φ1.2 | 150 | |
YLC-1000 | 40 | 360 | DN100/4" | 6 | matched | 100×21.9×50 | 60×11×Φ1.2 | 160 | |
YLC-1200 | 50 | 400 | DN125/5" | 6 | matched | 100×21.9×50 | 60×11×Φ1.2 | 180 | |
YLC-1500 | 60 | 420 | DN150/6" | 6 | matched | 170×27.3×57 | 120×16×Φ1.4 | 210 | |
YLC-2000 | 80 | 560 | DN150/6" | 6 | matched | 170×27.3×57 | 120×16×Φ1.4 | 220 | |
YLC-2500 | 100 | 700 | DN150/6" | 6 | matched | 170×27.3×57 | 60×128×30 (W×H×T) | 120×16×Φ1.4 | 275 |
YLC-3000 | 125 | 840 | DN150/6" | 6 | matched | 173×27.3×57 | 120×16×Φ1.4 | 300 | |
YLC-4000 | 150 | 1120 | DN200/8" | 6 | matched | 173×32.5×65 | 120×20×Φ1.6 | 325 | |
YLC-5000 | 200 | 1400 | DN200/8" | 6 | matched | 173×37.7×72 | 120×22×Φ1.6 | 350 | |
YLC-7000 | 300 | 2100 | DN250/10" | 6 | matched | 175×42.6×80 | 120×24×Φ2.0 | 400 | |
YLC-10K | 400 | 2520 | DN250/10" | 6 | matched | 176×52.9×95 | 60×150×40 (W×H×T) | 120×28×Φ2.2 | 475 |
YLC-15K | 600 | 3080 | DN300/12" | 6 | matched | 176×78×110 | 120×32×Φ2.4 | 600 | |
YLC-20K | 800 | 3920 | DN350/14" | 6 | matched | confirmed | confirmed | confirmed | confirmed |
YLC-25K | 1000 | 4760 | DN350/14" | 6 | matched | confirmed | confirmed | confirmed |
Product Categories : Ultraviolet Sterilizer > UV Water Sterilizer
Premium Related Products
Other Products
Hot Products
Air Conditioner Condenser Tube Cleaning EquipmentChilled Water Treatment Rapid Quartz Sand FilterHair Collector Filter for Swimming PoolPool Disinfection Water System Chlorine Dioxide GeneratorSUS 304 Bag Filter Housing and PP Filtering Cartridgeby Pass Flow Water Processor Side Stream Treatment (YLD-II-G)Stainless Steel or Carbon Steel Swimming Pool Hair FilterElectromagnetic Water Treatment with High FrequencyYlc-200 Immersion Ultraviolet Sterilizer Water Purifier Without Secondary PollutionOpen Channel UV Water Sterilizer System with Automatic ControlAuto Cleaning Brush Type Water Filter for 100/200 Micron Coarse Filtration10000 Gauss Strong Water Magnetic Treatment Filter in Agriculture DesalinationStainless Steel Bag Filter Housing 0.5um Liquid Filtration Water PurifcationIndustrial Water UV Sterilizer, Water Purifying UV Light SterilizerAutomatic Backwash Self Cleaning Stainless Steel Cartridge Water FilterCirculating Water System Automatic Sand Media Water Filter (YL-SF-500)