Chamber Closed Self Cleaning UV Disinfection System Waste Water Treatment
Basic Info
Model No.: YLC-700
Product Description
Model NO.: YLC-700 Application: Industry Disinfection Method: Ultraviolet Material: Stainless Steel Ss304, Ss316 Interface Type: Flange or Thread Alert System for Lamp: One Set Raw Water Supplying: Running Water Inlet & Outlet Diameter: 4 Inch Specification: CE, SGS, ISO HS Code: 8421219990 Certification: ISO9001, SGS, CE Voltage: 110V/220V/380V Bactericidal Efficienc: 98% Kill Total Coliforms Lifespan of UV Lamp: 9000-12000 Hours Flow Rate: 30 Ton/Hour System Working Pressure Resistance: (0.6 MPa)6kg/Cm2 Brand of Ballast: Beasun Trademark: YLD Origin: Jiangyin, Jiangsu Chamber Closed Self Cleaning UV Disinfection System Waste Water Treatment
What factors influence the effectiveness of UV sterilizers?
Size and type of organism: Theoretically UV radiation can kill viruses, bacteria, algae, and protozoa. In general, larger organisms, such as protozoa, require a higher dose of UV radiation than smaller organisms, such as bacteria. But there are also differences between various organisms of the same type: some bacteria are more resistant to UV radiation than others.
Power of bulb: The amount of UV light produced by the bulb is reflected in the wattage of the bulb. Bulbs with a higher wattage produce more UV light. The ability of the germicidal fluorescent lamp to produce UV light decreases with age, and in most cases, the bulb needs replacement every 6 months. UV light is best produced at temperatures of 104-110ºF; cooler temperatures will result in less output.
UV penetration: If the UV light can not penetrate the water, it will not be effective. Higher water turbidity will decrease penetration. UV sterilizers should be placed after the biological and mechanical filters so the water is as clear as possible when it enters the sterilizer. Salinity also affects penetration; UV light penetrates freshwater better than saltwater. Finally, cleanliness of the lamp or sleeve is important. If a film or mineral deposit covers the lamp or sleeve, the light will be partially or totally blocked. The distance of the lamp from the water also influences the effectiveness. UV light will only penetrate clear saltwater to a depth of 5mm.
Contact time: The longer the amount of time the water is being exposed to the UV light, the more killing power is available. The contact time, sometimes referred to as "dwell time," is influenced by flow rate of the water: slower flow rates increase contact time. The length of the bulb also affects the contact time; with a longer bulb, the water is in contact with the UV light for a longer period of time. Another variable to consider is the turnover time (amount of time required to have the entire volume of water in the aquarium pass through the sterilizer). Since the "sterilized" water constantly mixes with the water in the aquarium as it returns, it is impossible to "sterilize" all the water in the aquarium.
FAQ:
01. What is the source of raw water to be treated?
-- is it underground water or well water? or river water ,other source?
02. What is the capacity(m3/hour) you required for this sterilizer?
-- most IMPORTANT requirement.
03. What will the treated water be used for?
--for human drinking or industry purpose?
04. What is the power supply in your country?
220V/60Hz or other?
Contact us if you need more details on UV Sterilizer. We are ready to answer your questions on packaging, logistics, certification or any other aspects about UV Water Purifier、Germicidal UV Lamp. If these products fail to match your need, please contact us and we would like to provide relevant information.
What factors influence the effectiveness of UV sterilizers?
Size and type of organism: Theoretically UV radiation can kill viruses, bacteria, algae, and protozoa. In general, larger organisms, such as protozoa, require a higher dose of UV radiation than smaller organisms, such as bacteria. But there are also differences between various organisms of the same type: some bacteria are more resistant to UV radiation than others.
Power of bulb: The amount of UV light produced by the bulb is reflected in the wattage of the bulb. Bulbs with a higher wattage produce more UV light. The ability of the germicidal fluorescent lamp to produce UV light decreases with age, and in most cases, the bulb needs replacement every 6 months. UV light is best produced at temperatures of 104-110ºF; cooler temperatures will result in less output.
UV penetration: If the UV light can not penetrate the water, it will not be effective. Higher water turbidity will decrease penetration. UV sterilizers should be placed after the biological and mechanical filters so the water is as clear as possible when it enters the sterilizer. Salinity also affects penetration; UV light penetrates freshwater better than saltwater. Finally, cleanliness of the lamp or sleeve is important. If a film or mineral deposit covers the lamp or sleeve, the light will be partially or totally blocked. The distance of the lamp from the water also influences the effectiveness. UV light will only penetrate clear saltwater to a depth of 5mm.
Contact time: The longer the amount of time the water is being exposed to the UV light, the more killing power is available. The contact time, sometimes referred to as "dwell time," is influenced by flow rate of the water: slower flow rates increase contact time. The length of the bulb also affects the contact time; with a longer bulb, the water is in contact with the UV light for a longer period of time. Another variable to consider is the turnover time (amount of time required to have the entire volume of water in the aquarium pass through the sterilizer). Since the "sterilized" water constantly mixes with the water in the aquarium as it returns, it is impossible to "sterilize" all the water in the aquarium.
FAQ:
01. What is the source of raw water to be treated?
-- is it underground water or well water? or river water ,other source?
02. What is the capacity(m3/hour) you required for this sterilizer?
-- most IMPORTANT requirement.
03. What will the treated water be used for?
--for human drinking or industry purpose?
04. What is the power supply in your country?
220V/60Hz or other?
Model | Amount of disinfectant | Power (W) | Incoming and outcoming water pipes (Nominal/ British system) | System pressure resistance (Kg/cm²) | UV light fault Alarm | Dimension of the reactor (cm) L×W×H | Dimension of the control cabinet (cm) | Anchor screws | Transport weight(Kg) |
YLCn-005 | 0.3 | 16 | 1/2″ | 6 | Has | 30×6×11 | | | 5 |
YLCn-008 | 1 | 25 | 1/2″ | 6 | Has | 47×6.3×11 | | | 10 |
YLCn-050 | 2 | 40 | 1″ | 6 | Has | 100×9×20 | Φ8.9×25 (d×L) | 69×4×Φ1 | 25 |
YLCn-150 | 6 | 80 | 1+1/4″ | 6 | Has | 100×11×23 | 69×4×Φ1 | 30 | |
YLCn-200 | 8 | 120 | 1+1/2″ | 6 | Has | 100×15.9×30 | Φ8.9×45 (d×L) | 69×7×Φ1 | 35 |
YLCn-300 | 12 | 160 | 2″ | 6 | Has | 100×15.9×32 | 69×7×Φ1 | 40 | |
YLC-050 | 2 | 40 | DN25/1″ | 6 | Has | 100×8.9×30 | 25×30×12 (W×H×D) | 60×4×Φ1 | 45 |
YLC-150 | 6 | 80 | DN32/11/4″ | 6 | Has | 100×10.8×30 | 60×4×Φ1 | 50 | |
YLC-200 | 8 | 120 | DN40/11/2″ | 6 | Has | 100×15.9×40 | 60×7×Φ1 | 60 | |
YLC-300 | 12 | 160 | DN50/2″ | 6 | Has | 100×15.9×40 | 60×7×Φ1 | 70 | |
YLC-360 | 15 | 200 | DN65/21/2″ | 6 | Has | 100×15.9×40 | 60×7×Φ1 | 120 | |
YLC-500 | 20 | 240 | DN65/21/2″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 130 | |
YLC-600 | 25 | 280 | DN80/3″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 140 | |
YLC-700 | 30 | 320 | DN100/4″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 150 | |
YLC-1000 | 40 | 360 | DN100/4″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 160 | |
YLC-1200 | 50 | 400 | DN125/5″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 180 | |
YLC-1500 | 60 | 420 | DN150/6″ | 6 | Has | 170×27.3×57 | 120×16×Φ1.4 | 210 | |
YLC-2000 | 80 | 560 | DN150/6″ | 6 | Has | 170×27.3×57 | 120×16×Φ1.4 | 220 | |
YLC-2500 | 100 | 700 | DN150/6″ | 6 | Has | 170×27.3×57 | 60×128×30 (W×H×D) | 120×16×Φ1.4 | 275 |
YLC-3000 | 125 | 840 | DN150/6″ | 6 | Has | 170×27.3×57 | 120×16×Φ1.4 | 300 | |
YLC-4000 | 150 | 1120 | DN200/8″ | 6 | Has | 173×32.5×65 | 120×20×Φ1.6 | 325 | |
YLC-5000 | 200 | 1400 | DN200/8″ | 6 | Has | 173×37.7×72 | 120×22×Φ1.6 | 350 | |
YLC-7000 | 300 | 2100 | DN250/10″ | 6 | Has | 175×42.6×80 | 120×24×Φ2.0 | 400 | |
YLC-10K | 400 | 2520 | DN250/10″ | 6 | Has | 176×52.9×95 | 60×150×40 (W×H×D) | 120×22×Φ2.2 | 475 |
YLC-15K | 600 | 3080 | DN300/12″ | 6 | Has | 176×78×110 | 120×32×Φ2.4 | 600 | |
YLC-20K | 800 | 3920 | DN350/14″ | 6 | Has | Designated | Designated | Designated | Designated |
YLC-25K | 1000 | 4760 | DN350/14″ | 6 | Has | Designated | Designated | Designated | Designated |
Contact us if you need more details on UV Sterilizer. We are ready to answer your questions on packaging, logistics, certification or any other aspects about UV Water Purifier、Germicidal UV Lamp. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Ultraviolet Sterilizer > UV Water Sterilizer
Email to this supplier
Premium Related Products
Other Products
Hot Products
Air Conditioner Condenser Tube Cleaning EquipmentChilled Water Treatment Rapid Quartz Sand FilterHair Collector Filter for Swimming PoolPool Disinfection Water System Chlorine Dioxide GeneratorSUS 304 Bag Filter Housing and PP Filtering Cartridgeby Pass Flow Water Processor Side Stream Treatment (YLD-II-G)Stainless Steel or Carbon Steel Swimming Pool Hair FilterElectromagnetic Water Treatment with High FrequencyYlc-200 Immersion Ultraviolet Sterilizer Water Purifier Without Secondary PollutionOpen Channel UV Water Sterilizer System with Automatic ControlAuto Cleaning Brush Type Water Filter for 100/200 Micron Coarse Filtration10000 Gauss Strong Water Magnetic Treatment Filter in Agriculture DesalinationStainless Steel Bag Filter Housing 0.5um Liquid Filtration Water PurifcationIndustrial Water UV Sterilizer, Water Purifying UV Light SterilizerAutomatic Backwash Self Cleaning Stainless Steel Cartridge Water FilterCirculating Water System Automatic Sand Media Water Filter (YL-SF-500)