220V/380V UV Water Disinfection for Swimming Pool Water
Basic Info
Model No.: YLC-1000
Product Description
Model NO.: YLC-1000 Application: Industry Disinfection Method: Ultraviolet Material: Stainless Steel Ss304, Ss316 Interface Type: Flange Alert System for Lamp: One Set Raw Water Supplying: Running Water Inlet & Outlet Diameter: 4 Inch Specification: CE, SGS, ISO HS Code: 8421219990 Certification: ISO9001, SGS, CE Voltage: 110V/220V/380V Bactericidal Efficienc: 98% Kill Total Coliforms Lifespan of UV Lamp: 9000-12000 Hours Flow Rate: 40 Ton/Hour System Working Pressure Resistance: (0.6 MPa)6kg/Cm2 Brand of Ballast: Beasun Trademark: YLD Origin: Jiangyin, Jiangsu 220V/380V UV Water Disinfection For Swimming Pool Water
Optimal service condition:
As UV is a short- wavelength light wave, it has low radiant energy and weak penetrating power and can only kill the microorganisms it directly radiates on. Therefore, in order to enhance the bacteria-killing efficiency and ensure the security of drinking water, the incoming water into the sterilizer must meet the following standard, (and if exceeding the following standard, the killing efficiency may be affected).
Q: Is UV 100% effective?
A: UV disinfection typically offers a 99.99% reduction in both bacteria and virus and is more effective than chemical disinfection processes at destroying viruses.
Q: Does UV remove E. coli?
A: Yes, E. coli requires a UV dose of between 6 to 12 mJ/cm2 to achieve 4-log disinfection. This is well within the capabilities of the Sterilight UV system.
Q: How much does it cost to operate?
A: UV systems are extremely economical to operate.
A typical household UV system operates on the same power requirements as a 40 watt light bulb!
Q:Will UV change the taste or smell of my water?
A:UV is a physical disinfection process, no additives are required. It does not change the taste or odour of the water. It simply provides safe reliable disinfection.
Q: How do I know the system is working?
A: All UV systems come with "lamp-out" monitors which give an audible and visual signal in case of lamp failure. Sterilight GOLD systems incorporate true UV intensity monitors so an alarm will sound if the disinfection effectiveness falls below a safe level.
Q: Why do I need Disinfection?
A: Disinfection is required on all water supplies that are not protected by a municipal water source. Due to the uncertainties that exist within some water systems, we can no longer rely on the fact that our water supplies "may be safe." By providing your own disinfection, you are taking the responsibility of ensuring the safety of the water supply for you and your family.
FAQ:
01. What is the source of raw water to be treated?
-- is it underground water or well water? or river water ,other source?
02. What is the capacity(m3/hour) you required for this sterilizer?
-- most IMPORTANT requirement.
03. What will the treated water be used for?
--for human drinking or industry purpose?
04. What is the power supply in your country?
220V/60Hz or other?
Contact us if you need more details on UV Sterilizer. We are ready to answer your questions on packaging, logistics, certification or any other aspects about UV Water Sterilizer、Water Treatment Plant. If these products fail to match your need, please contact us and we would like to provide relevant information.
Optimal service condition:
As UV is a short- wavelength light wave, it has low radiant energy and weak penetrating power and can only kill the microorganisms it directly radiates on. Therefore, in order to enhance the bacteria-killing efficiency and ensure the security of drinking water, the incoming water into the sterilizer must meet the following standard, (and if exceeding the following standard, the killing efficiency may be affected).
Total iron content | Less than 0.3ppm(0.3mg/L) |
H2S | Less than 0.05ppm(0.05mg/L) |
Total suspended matter | Less than 10 mg/L |
Manganese content | Less than 0.05 mg/L |
Water hardness | Less than 120 mg/L |
Chroma | Less than 15centigrade |
Water Temp. | 5-60Centigrade |
PH value | 6.5-8 |
Interface type | flange or thread |
Q: Is UV 100% effective?
A: UV disinfection typically offers a 99.99% reduction in both bacteria and virus and is more effective than chemical disinfection processes at destroying viruses.
Q: Does UV remove E. coli?
A: Yes, E. coli requires a UV dose of between 6 to 12 mJ/cm2 to achieve 4-log disinfection. This is well within the capabilities of the Sterilight UV system.
Q: How much does it cost to operate?
A: UV systems are extremely economical to operate.
A typical household UV system operates on the same power requirements as a 40 watt light bulb!
Q:Will UV change the taste or smell of my water?
A:UV is a physical disinfection process, no additives are required. It does not change the taste or odour of the water. It simply provides safe reliable disinfection.
Q: How do I know the system is working?
A: All UV systems come with "lamp-out" monitors which give an audible and visual signal in case of lamp failure. Sterilight GOLD systems incorporate true UV intensity monitors so an alarm will sound if the disinfection effectiveness falls below a safe level.
Q: Why do I need Disinfection?
A: Disinfection is required on all water supplies that are not protected by a municipal water source. Due to the uncertainties that exist within some water systems, we can no longer rely on the fact that our water supplies "may be safe." By providing your own disinfection, you are taking the responsibility of ensuring the safety of the water supply for you and your family.
FAQ:
01. What is the source of raw water to be treated?
-- is it underground water or well water? or river water ,other source?
02. What is the capacity(m3/hour) you required for this sterilizer?
-- most IMPORTANT requirement.
03. What will the treated water be used for?
--for human drinking or industry purpose?
04. What is the power supply in your country?
220V/60Hz or other?
Model | Amount of disinfectant | Power (W) | Incoming and outcoming water pipes (Nominal/ British system) | System pressure resistance (Kg/cm²) | UV light fault Alarm | Dimension of the reactor (cm) L×W×H | Dimension of the control cabinet (cm) | Anchor screws | Transport weight(Kg) |
YLCn-005 | 0.3 | 16 | 1/2″ | 6 | Has | 30×6×11 | | | 5 |
YLCn-008 | 1 | 25 | 1/2″ | 6 | Has | 47×6.3×11 | | | 10 |
YLCn-050 | 2 | 40 | 1″ | 6 | Has | 100×9×20 | Φ8.9×25 (d×L) | 69×4×Φ1 | 25 |
YLCn-150 | 6 | 80 | 1+1/4″ | 6 | Has | 100×11×23 | 69×4×Φ1 | 30 | |
YLCn-200 | 8 | 120 | 1+1/2″ | 6 | Has | 100×15.9×30 | Φ8.9×45 (d×L) | 69×7×Φ1 | 35 |
YLCn-300 | 12 | 160 | 2″ | 6 | Has | 100×15.9×32 | 69×7×Φ1 | 40 | |
YLC-050 | 2 | 40 | DN25/1″ | 6 | Has | 100×8.9×30 | 25×30×12 (W×H×D) | 60×4×Φ1 | 45 |
YLC-150 | 6 | 80 | DN32/11/4″ | 6 | Has | 100×10.8×30 | 60×4×Φ1 | 50 | |
YLC-200 | 8 | 120 | DN40/11/2″ | 6 | Has | 100×15.9×40 | 60×7×Φ1 | 60 | |
YLC-300 | 12 | 160 | DN50/2″ | 6 | Has | 100×15.9×40 | 60×7×Φ1 | 70 | |
YLC-360 | 15 | 200 | DN65/21/2″ | 6 | Has | 100×15.9×40 | 60×7×Φ1 | 120 | |
YLC-500 | 20 | 240 | DN65/21/2″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 130 | |
YLC-600 | 25 | 280 | DN80/3″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 140 | |
YLC-700 | 30 | 320 | DN100/4″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 150 | |
YLC-1000 | 40 | 360 | DN100/4″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 160 | |
YLC-1200 | 50 | 400 | DN125/5″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 180 | |
YLC-1500 | 60 | 420 | DN150/6″ | 6 | Has | 170×27.3×57 | 120×16×Φ1.4 | 210 | |
YLC-2000 | 80 | 560 | DN150/6″ | 6 | Has | 170×27.3×57 | 120×16×Φ1.4 | 220 | |
YLC-2500 | 100 | 700 | DN150/6″ | 6 | Has | 170×27.3×57 | 60×128×30 (W×H×D) | 120×16×Φ1.4 | 275 |
YLC-3000 | 125 | 840 | DN150/6″ | 6 | Has | 170×27.3×57 | 120×16×Φ1.4 | 300 | |
YLC-4000 | 150 | 1120 | DN200/8″ | 6 | Has | 173×32.5×65 | 120×20×Φ1.6 | 325 | |
YLC-5000 | 200 | 1400 | DN200/8″ | 6 | Has | 173×37.7×72 | 120×22×Φ1.6 | 350 | |
YLC-7000 | 300 | 2100 | DN250/10″ | 6 | Has | 175×42.6×80 | 120×24×Φ2.0 | 400 | |
YLC-10K | 400 | 2520 | DN250/10″ | 6 | Has | 176×52.9×95 | 60×150×40 (W×H×D) | 120×22×Φ2.2 | 475 |
YLC-15K | 600 | 3080 | DN300/12″ | 6 | Has | 176×78×110 | 120×32×Φ2.4 | 600 | |
YLC-20K | 800 | 3920 | DN350/14″ | 6 | Has | Designated | Designated | Designated | Designated |
YLC-25K | 1000 | 4760 | DN350/14″ | 6 | Has | Designated | Designated | Designated | Designated |
Product Categories : Ultraviolet Sterilizer > UV Water Sterilizer
Email to this supplier
Premium Related Products
Other Products
Hot Products
Air Conditioner Condenser Tube Cleaning EquipmentChilled Water Treatment Rapid Quartz Sand FilterHair Collector Filter for Swimming PoolPool Disinfection Water System Chlorine Dioxide GeneratorSUS 304 Bag Filter Housing and PP Filtering Cartridgeby Pass Flow Water Processor Side Stream Treatment (YLD-II-G)Stainless Steel or Carbon Steel Swimming Pool Hair FilterElectromagnetic Water Treatment with High FrequencyYlc-200 Immersion Ultraviolet Sterilizer Water Purifier Without Secondary PollutionOpen Channel UV Water Sterilizer System with Automatic ControlAuto Cleaning Brush Type Water Filter for 100/200 Micron Coarse Filtration10000 Gauss Strong Water Magnetic Treatment Filter in Agriculture DesalinationStainless Steel Bag Filter Housing 0.5um Liquid Filtration Water PurifcationIndustrial Water UV Sterilizer, Water Purifying UV Light SterilizerAutomatic Backwash Self Cleaning Stainless Steel Cartridge Water FilterCirculating Water System Automatic Sand Media Water Filter (YL-SF-500)