300t/H High Efficiency UV Sterilizer for Viruses and Bacteria
Basic Info
Model No.: YLC-7000
Product Description
Model NO.: YLC-7000 Application: Industry Disinfection Method: Ultraviolet Material: Stainless Steel Ss304, Ss316 Lifespan of UV Lamp: 9000-12000 Hours Flow Rate: 0.3--1000 Ton/Hour System Working Pressure Resistance: (0.6 Mpa)6kg/Cm2 Brand of Ballast: Beasun Specification: CE, SGS HS Code: 8421219990 Certification: BV, ISO9001, SGS, CE Voltage: 110V/220V/380V Bactericidal Efficienc: 98% Kill Total Coliforms Medium Material: PP (Propene Polymer) Interface Type: Flange or Thread Alert System for Lamp: One Set Raw Water Supplying: Running Water Trademark: YLD Origin: Jiangyin, Jiangsu 300t/H High Efficiency UV Sterilizer For Viruses And Bacteria
Use
The UV sterilization equipment uses the ultraviolet ray the characteristic, kills extinguishes in the water the bacterium, the virus, the yeast, the mold and the algae biology, does not have to increase any chemicals and does not have to heat up or cooling, namely can achieve the disinfection effect, therefore widely is suitable to the electronics industry hyper pure aqueous system makes the running water sterilization to use, also is suitable for, drink, chemistry,cosmetics raw material for industry water and so on the medicine,drinks with the pure water, the mineral water, the cleaning aqueous system makes the running water sterilization to use, to water supply system and so on institution association, high-quality hotel, public place, also is the ideal hygienic guard decontaminating apparatus.
Installs the method
1st, this UV sterilization equipment uses when should be vertical either straight lie the laying aside or twists on the support, meets the water pipe to be supposed the bottom to enter outdoes.
2nd, first opens the inlet valve gate slowly to enter the water, after and so on the hydraulic pressure is stable waits a bit one, two minutes, then installs the Ultraviolet Lamp tube the circular telegram to start to work, service condition observation acoustic optics alarm system.
3rd, this UV sterilization equipment uses when should the continuous observation ultraviolet lamp tube color whether is weaken, changes color and extinguishes above, if has the situation namely to have to exchange the new lamp tube; In the normal service condition, the lamp tube service life approximately is 9,000 hours, at the appointed time should replace the new lamp tube, guarantees the sterilization effect.
Contact us if you need more details on Water Purifier. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Water Treatment、Water Treatment Plant. If these products fail to match your need, please contact us and we would like to provide relevant information.
Use
The UV sterilization equipment uses the ultraviolet ray the characteristic, kills extinguishes in the water the bacterium, the virus, the yeast, the mold and the algae biology, does not have to increase any chemicals and does not have to heat up or cooling, namely can achieve the disinfection effect, therefore widely is suitable to the electronics industry hyper pure aqueous system makes the running water sterilization to use, also is suitable for, drink, chemistry,cosmetics raw material for industry water and so on the medicine,drinks with the pure water, the mineral water, the cleaning aqueous system makes the running water sterilization to use, to water supply system and so on institution association, high-quality hotel, public place, also is the ideal hygienic guard decontaminating apparatus.
Installs the method
1st, this UV sterilization equipment uses when should be vertical either straight lie the laying aside or twists on the support, meets the water pipe to be supposed the bottom to enter outdoes.
2nd, first opens the inlet valve gate slowly to enter the water, after and so on the hydraulic pressure is stable waits a bit one, two minutes, then installs the Ultraviolet Lamp tube the circular telegram to start to work, service condition observation acoustic optics alarm system.
3rd, this UV sterilization equipment uses when should the continuous observation ultraviolet lamp tube color whether is weaken, changes color and extinguishes above, if has the situation namely to have to exchange the new lamp tube; In the normal service condition, the lamp tube service life approximately is 9,000 hours, at the appointed time should replace the new lamp tube, guarantees the sterilization effect.
Model | Amount of disinfectant | Power (W) | Incoming and outcoming water pipes (Nominal/ British system) | System pressure resistance (Kg/cm²) | UV light fault Alarm | Dimension of the reactor (cm) L×W×H | Dimension of the control cabinet (cm) | Anchor screws | Transport weight(Kg) |
YLCn-005 | 0.3 | 16 | 1/2″ | 6 | Has | 30×6×11 | 5 | ||
YLCn-008 | 1 | 25 | 1/2″ | 6 | Has | 47×6.3×11 | 10 | ||
YLCn-050 | 2 | 40 | 1″ | 6 | Has | 100×9×20 | Φ8.9×25 (d×L) | 69×4×Φ1 | 25 |
YLCn-150 | 6 | 80 | 1+1/4″ | 6 | Has | 100×11×23 | 69×4×Φ1 | 30 | |
YLCn-200 | 8 | 120 | 1+1/2″ | 6 | Has | 100×15.9×30 | Φ8.9×45 (d×L) | 69×7×Φ1 | 35 |
YLCn-300 | 12 | 160 | 2″ | 6 | Has | 100×15.9×32 | 69×7×Φ1 | 40 | |
YLC-050 | 2 | 40 | DN25/1″ | 6 | Has | 100×8.9×30 | 25×30×12 (W×H×D) | 60×4×Φ1 | 45 |
YLC-150 | 6 | 80 | DN32/11/4″ | 6 | Has | 100×10.8×30 | 60×4×Φ1 | 50 | |
YLC-200 | 8 | 120 | DN40/11/2″ | 6 | Has | 100×15.9×40 | 60×7×Φ1 | 60 | |
YLC-300 | 12 | 160 | DN50/2″ | 6 | Has | 100×15.9×40 | 60×7×Φ1 | 70 | |
YLC-360 | 15 | 200 | DN65/21/2″ | 6 | Has | 100×15.9×40 | 60×7×Φ1 | 120 | |
YLC-500 | 20 | 240 | DN65/21/2″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 130 | |
YLC-600 | 25 | 280 | DN80/3″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 140 | |
YLC-700 | 30 | 320 | DN100/4″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 150 | |
YLC-1000 | 40 | 360 | DN100/4″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 160 | |
YLC-1200 | 50 | 400 | DN125/5″ | 6 | Has | 100×21.9×50 | 60×11×Φ1.2 | 180 | |
YLC-1500 | 60 | 420 | DN150/6″ | 6 | Has | 170×27.3×57 | 120×16×Φ1.4 | 210 | |
YLC-2000 | 80 | 560 | DN150/6″ | 6 | Has | 170×27.3×57 | 120×16×Φ1.4 | 220 | |
YLC-2500 | 100 | 700 | DN150/6″ | 6 | Has | 170×27.3×57 | 60×128×30 (W×H×D) | 120×16×Φ1.4 | 275 |
YLC-3000 | 125 | 840 | DN150/6″ | 6 | Has | 170×27.3×57 | 120×16×Φ1.4 | 300 | |
YLC-4000 | 150 | 1120 | DN200/8″ | 6 | Has | 173×32.5×65 | 120×20×Φ1.6 | 325 | |
YLC-5000 | 200 | 1400 | DN200/8″ | 6 | Has | 173×37.7×72 | 120×22×Φ1.6 | 350 | |
YLC-7000 | 300 | 2100 | DN250/10″ | 6 | Has | 175×42.6×80 | 120×24×Φ2.0 | 400 | |
YLC-10K | 400 | 2520 | DN250/10″ | 6 | Has | 176×52.9×95 | 60×150×40 (W×H×D) | 120×22×Φ2.2 | 475 |
YLC-15K | 600 | 3080 | DN300/12″ | 6 | Has | 176×78×110 | 120×32×Φ2.4 | 600 | |
YLC-20K | 800 | 3920 | DN350/14″ | 6 | Has | Designated | Designated | Designated | Designated |
YLC-25K | 1000 | 4760 | DN350/14″ | 6 | Has | Designated | Designated | Designated | Designated |
Product Categories : Ultraviolet Sterilizer > UV Water Sterilizer
Premium Related Products
Other Products
Hot Products
Air Conditioner Condenser Tube Cleaning EquipmentChilled Water Treatment Rapid Quartz Sand FilterHair Collector Filter for Swimming PoolPool Disinfection Water System Chlorine Dioxide GeneratorSUS 304 Bag Filter Housing and PP Filtering Cartridgeby Pass Flow Water Processor Side Stream Treatment (YLD-II-G)Stainless Steel or Carbon Steel Swimming Pool Hair FilterElectromagnetic Water Treatment with High FrequencyYlc-200 Immersion Ultraviolet Sterilizer Water Purifier Without Secondary PollutionOpen Channel UV Water Sterilizer System with Automatic ControlAuto Cleaning Brush Type Water Filter for 100/200 Micron Coarse Filtration10000 Gauss Strong Water Magnetic Treatment Filter in Agriculture DesalinationStainless Steel Bag Filter Housing 0.5um Liquid Filtration Water PurifcationIndustrial Water UV Sterilizer, Water Purifying UV Light SterilizerAutomatic Backwash Self Cleaning Stainless Steel Cartridge Water FilterCirculating Water System Automatic Sand Media Water Filter (YL-SF-500)